Part Number Hot Search : 
SEF106B 5SERI GSBAT54S KDZTR30B TGS2313 CA3304M COMPO LTC2183
Product Description
Full Text Search
 

To Download TFS111 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS111.doc
Version 1.2
05.01.02
VI TELEFILTER
Filter Specification
TFS 111 - 1/4
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 C 0 dBm. for input: for output:
890 - 5,6 pF . 680 - 5,9 pF .
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 111 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (Reference level) Centre frequency ae
typ. value 11,9 111 dB MHz
tolerance / limit max. 14 111,0 0,06 dB MHz
fc at ambient temperature TA (fCAT)
Pass band at ambient temperature TA: Relative attenuation fC - 425 fC - 800 fC + 475 fC - 1395 fC + 1200 fC - 1535 fC + 1375 fC - 10 fC + 1500 kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... kHz ..... MHz ..... kHz ..... arel fC + 475 fC - 425 fC + 800 fC - 1210 fC + 1375 fC - 1395 fC + 1500 fC - 1535 fC + 10 kHz kHz kHz kHz kHz kHz kHz kHz MHz 60...45 45...55 1,13 160 3 10 C + 1,7 - 0,06
fC - 0,425 MHz........fC + 0,475 MHz
max. 3 max. 10 max. 10 min. 20 min. 20 min. 30 min. 30 dB dB s ns max 300 min. 40 min. 40
dB dB dB dB dB dB dB dB dB
Group delay ( mean value in pass band ): Group delay ripple (p-p) : fC - 800 kHz...fC + 800 kHz
ns
Deviation from linear phase (p-p): fC - 800 kHz...fC + 800 kHz Frequency inversion temperature ( To ) Temperature coefficient: 1-st order [ Tcf (1) ] 2-st order [ Tcf (2) ] Frequency deviation of fc over temperature: * ) Operating temperature range Storage temperature range Input power level
ppm/K ppm/K
fc(Hz) = [ Tcf(1) x (T - To) + Tcf(2) x (T - To) ] x fTo (MHz) - 10 C ... + 60 C - 40 C ... + 85 C max. + 10 dBm.
* ) fTo is reference frequence fc at frequency inversion temperature (To )
Generated: Checked/Approved:
Dunzow W.P. Dr. Bert Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS111.doc
Version 1.2
05.01.02
VI TELEFILTER
Filter Specification
TFS 111 - 2/4
3. Package and 50 - matching network (see Application Note): (All dimensions in mm)
TFS 111 tft L1
C1 C2
C1
C2
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS111.doc
Version 1.2
05.01.02
VI TELEFILTER
4. Stability Characteristics:
Filter Specification
TFS 111 - 3/4
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing:
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 1700 min 300 mm min 500 mm min 300 mm
Tape (all dimensions in mm) W Po Do D1 E F : : : : : : 24 4 1,5 0,3 0,1 + 0,5
Do Po
EMBOSSED CARRIER TAPE
P2
1,5 + 0,5 1,75 0,1 11,5 0,1 0,75 2 0,1 12 1,5 7,1 13,9 0,1
E Ao F W
D1 21,4
0,1
G (min) : P2 : P1 : D1(min) : Ao Bo : :
Bo
G
P1
0,2 0,2
COVER TAPE
W2
Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,4 +2 30,4 >= 90
C A N
13
0,25
W1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tap
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS111.doc
Version 1.2
05.01.02
VI TELEFILTER 5. Air reflow temperature conditions
Filter Specification
TFS 111 - 4/4
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.